Submersible Mixed Flow Pump Sizing: Design Flow and Head
News Published: 2026-10-30

Submersible Mixed Flow Pump Sizing: Design Flow and Head

Submersible mixed flow pump sizing starts with the volume you need to move, the time available, and the head the system requires. The result is a set of flow-and-head duties to check against model curves. A catalogue’s maximum flow cannot establish that a pump will meet those duties as water levels change.

For large water-transfer, irrigation, and drainage projects, record the intake, discharge route, liquid conditions, and power supply alongside the calculations. A pump may appear suitable on one duty point yet need further checks at another water level or operating arrangement.

This guide takes submersible mixed flow pump sizing from initial inputs to a comparable request for quotation (RFQ). It includes a simplified calculation example and the questions that remain before a model can be confirmed. For hydraulic definitions and broader equipment selection, use the mixed-flow pump selection guide.

Define the Outputs of Submersible Mixed Flow Pump Sizing

define the outputs of submersible mixed flow pump sizing

Start with a duty schedule

A useful submersible mixed flow pump sizing schedule records required flow, total dynamic head (TDH), operating hours, and the conditions behind each entry. List normal duty, drainage events, seasonal demand, and one-unit-out duty on separate rows.

InputRecord before requesting a model
Delivery targetVolume, required flow, operating period, and source of demand
Water levelsSimultaneous intake and receiving levels on one elevation datum
PipelineRoute, internal diameters, lengths, fittings, valves, and discharge boundary
LiquidTemperature, solids, sand, density, and relevant chemistry
Station arrangementRunning units, standby requirement, controls, and service access
Electrical supplyVoltage, frequency, starting constraints, and available controls

Give each value a unit and an evidence reference. Mark values that lack survey or operating records as assumptions. This keeps submersible mixed flow pump sizing traceable when a revised pipe route or water level changes the duty.

Set the equipment boundary

Does the review cover one pump, several pumps on a common main, or the whole station? State the boundary. Identify where the calculated head starts and ends. Otherwise, suppliers may include different pipe losses in apparently comparable offers.

Use the mixed-flow pump range as a starting point for available equipment, then request the exact model documents. Published family limits do not identify a confirmed operating point.

Submersible mixed flow pump sizing should also show what remains open: intake acceptance, permitted operating range, motor loading, and installation fit. These are review outputs alongside the preliminary flow-and-head figures.

Establish Design Flow and Drainage Duty

Convert the task into a flow requirement

For a fixed transfer volume with no incoming flow, a preliminary average flow is:

Q = V / t

Use cubic metres for volume V and hours for time t to obtain Q in m³/h. For hydraulic calculations using metres and seconds, divide m³/h by 3,600 to obtain m³/s. Keep the conversion visible in the calculation sheet.

For a basin that must drain while water flows in at a constant rate, a simple balance is:

Required average discharge = V / t + average inflow

That balance assumes the stated inflow, usable storage, and pumping availability apply over the period. Submersible mixed flow pump sizing for a stormwater station may instead require a time-dependent inflow and storage model. An average alone does not establish peak flood capacity or the water level reached during an event.

For irrigation, establish delivery periods and simultaneous demands. For continuous transfer, use the required delivery rate and operating schedule. Record any reserve requirement separately; do not add an unexplained percentage to several inputs.

Show availability and uncertainty

Illustrative scenario: An irrigation buyer needs to transfer 12,000 m³ during an 8-hour window. The arithmetic gives 1,500 m³/h if pumping is available throughout. Before asking for a model, the team checks whether outages or limits at either end reduce that window. This is a hypothetical planning example, not a completed installation.

Submersible mixed flow pump sizing changes if the available hours change. Record the change and calculate the duty again. Update the flow on the RFQ.

State whether the flow is a minimum delivery requirement, an average target, or a short-term peak. Those descriptions help the reviewer understand how proposed control and pump arrangements must be assessed.

Calculate Total Dynamic Head Across Water Levels

calculate total dynamic head across water levels

Separate elevation from losses

TDH is the energy per unit weight that the pump must add between the chosen system boundaries. For two large open water surfaces at the same atmospheric pressure, with negligible surface velocities, the simplified requirement is:

TDH = receiving water elevation - intake water elevation + total head losses

The Hydraulic Institute’s system-curve guidance explains the elevation, pressure, and friction terms. If the destination is pressurized or the boundaries have significant velocity, include the applicable pressure and velocity-head differences. Keep all terms in metres of the pumped liquid.

Do not confuse the pump’s installation depth with static lift. In submersible mixed flow pump sizing, the relevant elevation difference depends on the chosen boundaries and water surfaces. A deeper pump position does not simply add the same depth to the required discharge head.

Calculate pipe and component losses

Record pipe length, internal diameter, roughness assumptions, and each fitting or valve. The Darcy-Weisbach form for a straight pipe is:

h_f = f × (L / D) × v² / (2g)

Here f is the Darcy friction factor, L and D are in metres, v is mean velocity in m/s, and g is approximately 9.81 m/s². A component loss can be expressed as h_m = K × v² / (2g), using the coefficient and reference velocity appropriate to that component.

Use HI’s pipe-friction reference when documenting the method. Flow speed can differ between pipe sections. Include entry, exit, screen, or equipment losses where applicable, without counting them twice.

Submersible mixed flow pump sizing needs losses at the assessed flow, not one unexplained allowance for every operating condition. The pump outlet size alone does not establish an economical or suitable pipeline diameter.

Pair water levels that can occur together

Use one elevation datum for intake and receiving levels. Add rows for normal duty and high- and low-head cases that the site may face. Explain whether each pair comes from survey data, an operating requirement, or an assumption.

Submersible mixed flow pump sizing should identify both the highest required head and the lower-head conditions that may shift delivery and motor loading. Do not combine unrelated historical extremes without explaining why that pairing is a design case.

Check Submersible Mixed Flow Pump Sizing Against Curves

Review all proposed operating points

The duty schedule describes what the project requires. Actual flow depends on the interaction of the proposed pump and the system. The HI pump-and-system curve tutorial shows how their intersection establishes an operating point.

For submersible mixed flow pump sizing, ask the supplier to plot the relevant system conditions against the exact model curve. Label the speed, frequency, impeller setup, and curve version. Check the resulting points against the manufacturer’s permitted range and best efficiency point (BEP), where pump efficiency peaks.

For parallel operation, add individual pump flows at a common head when constructing the combined characteristic. Then find its interaction with the shared system. Two running pumps do not automatically provide twice the flow of one pump operating alone.

Keep power definitions clear

Hydraulic power transferred to the liquid is P_h = ρgQH. With density ρ in kg/m³, flow Q in m³/s, and head H in metres, the result is watts. Dividing by pump-only efficiency (hydraulic output divided by shaft input) gives shaft-power demand.

Motor and drive losses also affect electrical input. Check whether a quoted efficiency describes the pump alone or the complete pump set, so those losses are not counted twice. The definitions of pump efficiency and input power are explained in HI’s pump-curve reference.

Submersible mixed flow pump sizing must check loading over the assessed range, rather than choosing a motor solely from the normal point. Request the applicable power curve, rating, and operating limits. You can use an assumed efficiency for a labelled estimate. It does not establish actual electricity use.

Check the inlet and installation

Minimum submergence, inlet flow quality, and net positive suction head (NPSH) need separate attention. Water above the pump does not by itself establish adequate conditions against air entry or cavitation. HI’s submergence guidance provides background; use model-specific requirements for the proposal.

Illustrative scenario: A retrofit team completes preliminary submersible mixed flow pump sizing from the existing flow and pipe route. The proposed unit appears to fit, but the lowest operating level and removal opening remain unmeasured. The team requests those dimensions before accepting the arrangement. No installation outcome is implied.

Work Through an Illustrative Project Example

work through an illustrative project example

State the assumptions first

Illustrative scenario: A hypothetical drainage basin must remove 9,000 m³ of stored water in 3 hours while receiving a constant 500 m³/h. Assume continuous pumping availability, adequate storage, and the open-surface conditions described earlier. All following elevations and loss inputs are invented for this calculation, not Kairun performance data.

The preliminary submersible mixed flow pump sizing flow is:

  • Stored-water removal: 9,000 / 3 = 3,000 m³/h.
  • Add constant inflow: 3,000 + 500 = 3,500 m³/h.
  • Convert for power calculations: 3,500 / 3,600 = 0.9722 m³/s.

Suppose the normal intake surface is at elevation 10.0 m and the receiving surface at 15.0 m. The designer’s assumed total losses are 2.0 m at 3,500 m³/h. Normal static lift is 5.0 m and normal TDH is therefore 7.0 m.

Build the condition table

For this submersible mixed flow pump sizing example, hold the preliminary required flow at 3,500 m³/h and assume the same pipe configuration. The 2.0 m loss is a supplied assumption at that flow; no pipe geometry has been invented to make it look calculated.

Hypothetical conditionIntake levelReceiving levelStatic liftLoss at required flowRequired TDH
Normal10.0 m15.0 m5.0 m2.0 m7.0 m
Lower intake, higher receiver9.0 m16.0 m7.0 m2.0 m9.0 m
Higher intake, lower receiver11.0 m14.0 m3.0 m2.0 m5.0 m

These rows describe simultaneous assumed level pairs. They are required duties for review, not predictions that one fixed-speed pump will deliver exactly 3,500 m³/h in every row. Its actual intersections, controls, and allowable operation still need checking.

Using an assumed water density of 1,000 kg/m³, hydraulic power at the normal duty is 1,000 × 9.81 × (3,500 / 3,600) × 7 / 1,000 = 66.8 kW. At 9.0 m it is approximately 85.8 kW. Neither figure is the motor rating or electrical input.

The submersible mixed flow pump sizing result is a preliminary 3,500 m³/h requirement and a 5–9 m TDH duty envelope under the stated assumptions. No model has been selected. That decision still needs the actual curves. The next checks are actual losses, intake conditions, curves, motor loading, and how controls maintain the delivery requirement.

Send Kairun a duty table and pipeline information to request a model-specific review. Include the assumptions so the response can identify what still needs confirmation.

Prepare a Comparable Pump RFQ

Keep site and electrical details with the calculation

Submersible mixed flow pump sizing is only useful for procurement when the proposed equipment also fits the site. Record intake dimensions, nearby walls and screens, supports, outlet location, and the full lifting route. For a retrofit, check the drawing against the current opening and discharge connection.

State liquid temperature and expected sand, solids, or chemical conditions. Ask the supplier to identify wetted materials, seals, cable details, and protection functions for that liquid. Do not assume every model shares the same configuration or service life.

Confirm voltage, frequency, controls, starting method, and any variable-speed requirement. Ask what electrical items the quotation includes. Supply scope matters when comparing an equipment-only price with a package containing controls and accessories.

For a broader system checklist, consult the DOE pumping-system sourcebook. Use it alongside the project calculations and model documents.

Request evidence tied to the offer

Ask suppliers to return these documents against the same submersible mixed flow pump sizing schedule:

Required responseWhat to check
Proposed model and curveMarked duties, revision, speed, configuration, and operating limits
Power and motor dataDefinitions, ratings, and loading across the assessed range
Dimensional drawingInstallation position, connections, supports, and removal clearance
Intake requirementsMinimum operating level, submergence, and applicable inlet conditions
Materials and protectionActual included components and liquid limitations
Supply and acceptance scopeAccessories, exclusions, test documents, and applicable certificate scope

Review Kairun’s QH product information to begin the enquiry. Request current model-specific documents; do not combine general limits from different pages into a confirmed specification.

Submersible mixed flow pump sizing should remain linked to one project revision. If water levels or pipe routes change, update the schedule. Send the same version to each supplier. Compare technical fit and exclusions before comparing the total price.

Sizing Questions Before Model Approval

Can maximum flow and maximum head define a duty?

No. They may refer to different points on a curve. Submersible mixed flow pump sizing requires the needed flow at the applicable head, confirmed against the actual model and system conditions.

Should I add a standard percentage to every input?

Keep uncertainty and reserve requirements explicit. Repeated allowances in flow, losses, and head can obscure the actual design case. Have the responsible designer define the basis and check its effect on the proposed operating range.

Does the method also select an axial-flow pump?

The same project inputs help evaluate alternatives, but the proposed curves and installation limits decide suitability. Use the axial-flow versus mixed-flow comparison for background, then review the candidate models.

What if liquid or installation details are incomplete?

Keep the unresolved items visible. Submersible mixed flow pump sizing can establish preliminary duties, but the supplier still needs liquid data, intake dimensions, power information, and access requirements to assess the equipment.

What should I send for a useful quotation?

Send the duty table, calculation assumptions, pipe and intake drawings, liquid details, and electrical supply. Identify the documents and accessories required in the response. The final submersible mixed flow pump sizing review should resolve the model, operating range, and site interfaces before order approval.

Contact Kairun for a submersible mixed flow pump sizing review to request a proposal that addresses the same documented conditions.