Mixed flow pump efficiency is the hydraulic power delivered to the liquid divided by the power supplied to the pump shaft. Check it at your required flow and head. Use electrical input when calculating wire-to-water efficiency and electricity cost.
A higher catalogue percentage can still belong to the more costly choice. The number might describe a different duty, leave out motor losses, or apply only at the curve’s peak. You need to know what it measures before ranking two pumps.
For drainage, irrigation, and water-transfer projects, the pump must fit the site’s duty schedule. Changing water levels affect the head it must develop. The hours spent at each duty affect the annual bill.
This guide shows how to calculate efficiency, read it at the duty point, and compare yearly energy use. You’ll also find a checklist of data to request from suppliers. All worked figures are examples. The two named scenarios are fictional teaching examples, not customer cases.
Key Takeaways
- Pump efficiency uses shaft input; wire-to-water efficiency uses electrical input at a stated meter boundary.
- Compare mixed flow pump efficiency at the same flow, head, liquid conditions, and operating hours.
- A change from 80% to 85% is 5 percentage points; it does not automatically mean 5% energy savings.
- Peak efficiency and the best efficiency point do not define the pump’s full permitted operating range.
What Is a Good Mixed Flow Pump Efficiency?

A good mixed flow pump efficiency is one backed by the chosen model’s data at the duties your site needs. There is no single percentage that makes every mixed-flow pump a good choice. Speed, impeller settings, liquid properties, and duty all affect the result.
Compare the same kind of efficiency
A pump turns shaft power into power delivered to the liquid. Its motor turns electrical power into shaft power. Each step has its own losses.
Fictional scenario: Avery reviews two proposals for 2,000 m³/h at 12 m head. One quotes 80% pump efficiency; the other highlights 85% motor efficiency. Avery asks both suppliers for pump efficiency and electrical input at that duty.
They set aside the initial ranking because the figures measure different parts of the equipment. The result is a shared data request, not a proven saving. The original two numbers cannot settle which pump needs less power from the supply.
Keep catalogue figures tied to their models
Kairun’s published table lists 82% efficiency for the 350QH-35, with a 0° vane angle, at 1,404 m³/h and 16.32 m head. The listed speed is 980 r/min. This row does not establish wire-to-water efficiency or a verified site result.
To assess a candidate, review the QH mixed-flow model data and request its curve and efficiency definition. Ask what the power column means before using it in a formula. A motor rating is not a reading of shaft input or power drawn from the supply.
How to Calculate Mixed Flow Pump Efficiency
A mixed flow pump efficiency calculation starts with flow rate, total head, liquid density, and the right input power. Record them at the same duty. Don’t combine yesterday’s flow reading with today’s power reading.
The Hydraulic Institute’s pump-curve guidance defines pump efficiency as hydraulic output divided by pump input. Use shaft power for this pump-only check.
Calculate hydraulic output power
For a liquid whose density stays constant:
Hydraulic power (kW) = density × 9.81 × flow × total head / 1,000
Use density in kg/m³, flow in m³/s, and head in m. The value 9.81 is gravity in m/s². Divide flow in m³/h by 3,600 before using this formula.
Total head is the energy added per unit weight of liquid. Find it across the pump from the relevant pressure, height, and velocity-head differences. Static lift alone is not the full system duty. Include pipe friction and any other required head when defining that duty.
Illustrative calculation: Assume clean water at a density of 1,000 kg/m³, a flow of 2,000 m³/h, and 12 m total head:
Flow = 2,000 / 3,600 = 0.5556 m³/s
Hydraulic power = 1,000 × 9.81 × (2,000 / 3,600) × 12 / 1,000 = 65.4 kW
Use the unrounded flow value in the calculation. The result is power delivered to the liquid. It is not the power drawn from the supply.
Use shaft input for pump efficiency
Mixed flow pump efficiency = hydraulic power / shaft input power
If shaft input at this duty is 81.75 kW:
Pump efficiency = 65.4 / 81.75 = 0.80 = 80%
To estimate shaft input from a known mixed flow pump efficiency, rearrange the formula:
Shaft input = hydraulic power / pump efficiency
Use 0.80 in that formula, not 80. For site checks, agree how shaft power will be measured or estimated and how much error the method allows. Don’t use the motor nameplate rating just because it is easier to find.
Use electrical input for wire-to-water efficiency
Wire-to-water efficiency = hydraulic power / electrical input power
The ASHRAE pumping reference explains that equipment efficiency includes pump and motor losses. A variable-speed system also includes drive losses.
For a simple drive, motor, and pump chain, assume 80% pump efficiency, 95% motor efficiency, and 97% drive efficiency:
Wire-to-water efficiency = 0.80 × 0.95 × 0.97 = 73.72%
Report mixed flow pump efficiency and wire-to-water efficiency separately. Include other shaft-drive losses where they apply. State where the supply power is measured, especially if other station loads share the meter. Motor and drive losses change with duty; the fixed values here are only assumptions for this example.
Read Efficiency at Your Required Duty Point

A mixed flow pump efficiency curve shows how efficiency changes with flow at the stated speed and impeller setting. Read it alongside head and input power. A peak percentage without the matching flow and head gives only part of the picture.
Locate duty and best efficiency point
The best efficiency point (BEP) is where pump efficiency peaks at a given speed and impeller setting. The mixed flow pump best efficiency point helps with selection, but your site may need more than one duty.
First find where the pump curve meets the system curve. That is the operating point. Read efficiency and power at the same flow. Check the model, speed, impeller details, liquid conditions, and curve revision before comparing another offer.
For the full plotting process, read the mixed-flow pump curve guide. Keep mixed flow pump efficiency readings with each marked duty in the project file.
Check the duty schedule and limits
Review the water-level cases that matter to the project:
- Low, normal, and high receiving levels
- The matching levels at the pump inlet
- Duties that last for hours and brief peak events
- Relevant cases with several pumps running together
Ask the supplier to identify the preferred operating region (POR) and allowable operating region (AOR). POR is the range around BEP where efficiency and reliability are not substantially degraded. AOR is the wider permitted range subject to the manufacturer’s stated limits. BEP alone defines neither range.
The Hydraulic Institute’s operating-region explanation describes how flow away from BEP can enter the impeller at a less suitable angle. Check power loading and the required net positive suction head (NPSH) margin as well. Minimum submergence, the liquid depth above a defined pump reference, is a separate check.
A useful mixed flow pump efficiency review keeps these limits beside the energy figures. A low estimated bill cannot justify running outside the approved range.
Why Mixed Flow Pump Efficiency Falls in Service
A change in mixed flow pump efficiency can come from the duty, inlet flow, or pump condition. Compare current flow, head, speed, and input power with the baseline. A higher power reading alone does not prove a loss of efficiency.
Separate a changed duty from a loss
If the receiving water level rises, the pump may need to develop more head. A blocked screen or pipe changes the system resistance. Either change can move the operating point and alter power use.
Check mixed flow pump efficiency at the new point before deciding whether the impeller is worn. Energy per cubic metre also needs the matching head or water-level range. Lifting the same volume through a greater height requires more hydraulic energy, even if efficiency stays the same.
Review inlet flow and pump condition
Swirling flow and air drawn into the inlet can disturb the impeller flow. Low liquid depth can allow surface vortices to form. Uneven approach flow can also impair performance. More water depth alone will not solve every inlet problem.
Use the pump intake design guide to record approach flow, water levels, and sump dimensions. Keep inlet limits tied to the layout and selected model.
Wear can increase clearances and internal leakage. Deposits or debris can block passages. Compare mixed flow pump efficiency with a repeatable baseline before arranging checks under the equipment instructions and the site’s isolation procedure. Don’t change clearances or blade settings without the supplier’s review.
Compare Mixed Flow Pump Energy Costs Fairly

Mixed flow pump efficiency affects power use, but a fair cost comparison holds the hydraulic duty constant. Compare the same liquid, flow, head, hours, and meter boundary. Include motor and drive losses, plus other station loads where they form part of the quoted power.
Compare two efficiencies at one duty
Continue the illustrative 2,000 m³/h, 12 m clean-water example. Hydraulic output stays at 65.4 kW. Assume the same 95% motor efficiency and 97% drive efficiency in both cases. Change only pump efficiency.
| Quantity | Scenario A | Scenario B |
|---|---|---|
| Assumed pump efficiency | 80% | 85% |
| Hydraulic output | 65.40 kW | 65.40 kW |
| Shaft input | 81.75 kW | 76.94 kW |
| Electrical input | 88.71 kW | 83.50 kW |
| Wire-to-water efficiency | 73.72% | 78.33% |
Electrical input equals hydraulic output divided by the combined pump, motor, and drive efficiencies. The mixed flow pump efficiency increase is 5 percentage points. Under these fixed assumptions, power drawn from the supply falls by about 5.88%. These measure different parts of the change.
Calculate annual energy from the duty schedule
At 4,000 hours per year, the unrounded power difference gives about 20,874 kWh/year. At an assumed tariff of USD 0.10/kWh, that is about USD 2,087/year. These are worked examples, not measured savings or a Kairun promise.
For a real project, split the year into periods with known duties. Find each period’s power draw from the relevant pump, motor, and drive data. Multiply that power by the hours, then add the results. Use the stated energy tariffs and assess demand charges separately.
Fictional scenario: Rowan reviews an irrigation replacement using this 4,000-hour example. The existing pump’s meter covers several duties, while the new pump’s estimate uses only the 12 m duty. Rowan splits the meter record into periods and requests matching supplier data.
They keep USD 2,087 as a single-duty example. The replacement decision stays open until both annual estimates cover the same duties and hours. A valid calculation at one point does not prove the result for the whole year.
Before estimating mixed flow pump efficiency at a lower speed, check variable-speed operating limits. Affinity rules depend on stated assumptions. Static head and changes in efficiency can prevent a speed reduction from delivering the expected flow or saving.
What Efficiency Evidence Should You Request?
Request enough data to repeat the mixed flow pump efficiency comparison. Tie each figure to the same model, impeller setting, speed, and duty. Ask the supplier to mark open items so they don’t become hidden assumptions in the cost estimate.
| Record | What to confirm |
|---|---|
| Duty schedule | Flow and head together, liquid conditions, water levels, and hours |
| Marked performance curves | Model, speed, impeller setting, revision, and assessed duties |
| Efficiency and power basis | Shaft or electrical input, included losses, and meter boundary |
| Operating limits | POR, AOR, power loading, NPSH requirements, and minimum submergence |
| Test evidence | Test conditions, acceptance criteria, uncertainty, and report reference |
| Annual-cost inputs | Power at each duty, hours, tariff, other loads, and demand charges |
For site readings, ask how the instruments were checked. Confirm that staff took the readings at steady, matching conditions. Qualified staff should handle electrical tests under the approved site procedure. Voltage and current alone do not establish actual three-phase electrical kW.
A management-system certificate does not validate a model’s efficiency curve. Nor does a pump type or installation label prove lower power use. Keep claims about mixed flow pump efficiency tied to the records that support them.
Mixed Flow Pump Efficiency FAQs
What is a good efficiency for a mixed flow pump?
There is no universal percentage. Check mixed flow pump efficiency at the project’s flow, head, speed, impeller setting, and liquid conditions. A catalogue peak can help, but the duty schedule and permitted range decide whether the candidate fits the site.
How do I calculate mixed flow pump efficiency?
Divide hydraulic output power by shaft input power and multiply by 100 for a percentage. Find hydraulic output from density, flow, and total head using consistent units. Use matching electrical input instead when finding wire-to-water efficiency.
Is pump efficiency the same as motor efficiency?
No. A pump turns shaft power into useful liquid power; its motor turns electrical power into shaft power. Each step has losses. Include drive and other shaft-drive losses where relevant, and state which loads the supply-power reading covers.
Does a variable-frequency drive always improve efficiency?
No. A variable-frequency drive (VFD) changes speed and moves the operating point relative to the system curve. Whether it cuts yearly energy use depends on the duties, static head, hours, and losses. Check the supplier’s limits before choosing the speed range.
Are mixed flow pumps more efficient than axial flow pumps?
Neither type wins at every duty. Compare actual models at the same required flow and head, using the same power boundaries. The hydraulic type helps narrow the search. Model-specific curves and site needs settle the choice.
Put the comparison into a project decision
Start with one agreed duty schedule. Then link each efficiency figure to its input-power definition. That keeps pump-only performance separate from the power that appears on the bill. It also makes gaps between supplier proposals easier to resolve.
Next, check the permitted range alongside the energy estimate. Keep the model, curve revision, liquid conditions, water-level cases, and hours in the project file. A change to any of those inputs can change the result. Update the calculation when the site duty or control plan changes.
Treat an annual energy figure as an estimate until its duty and power basis are supported. The worked example shows the method; your project needs the relevant equipment and site records. Assess installation, service, and replacement costs separately when comparing total ownership cost.
To assess mixed flow pump efficiency for your project, discuss your duty and operating schedule with Kairun Pump. Send your flow, total dynamic head, liquid, water-level range, and operating hours. Ask for the proposed model, marked curves, and applicable test documents.